Commercial Push Pier Systems

The Foundation Supportworks Push Pier System utilizes high-strength round steel tubes and a load transfer bracket (retrofit foundation repair bracket) to stabilize and/or lift sinking or settling foundations. The foundation bracket is secured against the existing footing and pier sections are driven hydraulically through the foundation bracket and into the soil below using the combined structural weight and any contributory soil load as resistance. Pier sections are continuously driven until a suitable load-bearing stratum is encountered. At that point, the structure either begins to lift or the target pressure/load is achieved. The weight of the structure is then transferred from the unstable soil, to the foundation brackets, through the piers, and to firm load-bearing soil or bedrock.

The Foundation Supportworks Push Pier System develops a factor of safety against pier settlement by the pier installation methods used and the sequence with which multiple piers are driven and then re-loaded. Piers are first driven individually using the maximum weight of the structure and any contributory soil load. After all of the piers are driven, the piers are re-loaded simultaneously, and the total reaction load is distributed over the multiple pier locations. Since the average load on each pier during the load transfer operation is less than the load during pier installation/driving, a factor of safety against settlement is achieved. Typical factors of safety against pier settlement range from about 1.5 to 3.0, with higher values generally achieved for structures with greater rigidity. These factors of safety conservatively ignore any additional long-term frictional component to the pier's capacity (see below for more information).

Foundation Supportworks™ Model 288 Pier System Specifications

  • Bracket: Weldment manufactured from 0.25", 0.375", and 0.50"-thick steel plate. Yield strength = 36 ksi (min.), tensile strength = 58 ksi (min.).
  • External Sleeve: 3.50" OD x 0.216" wall x 30" or 48" long with sleeve collar welded to one end. Yield strength = 50 ksi (min.), tensile strength = 62 ksi (min.).
  • Pier Starter Tube: 2.875" OD x 0.165" wall x 50" long, triple-coated in-line galvanized. Yield strength = 50 ksi (min.), tensile strength = 55 ksi (min.). 3.375" OD x 0.188" wall x 1" long friction reducing collar welded to one end.
  • Pier Tube: 2.875" OD x 0.165" wall x 36" long, triple-coated in-line galvanized. Yield strength = 50 ksi (min.), tensile strength = 55 ksi (min.). 2.50" OD x 0.180" wall x 6" long internal coupler at one end with 3" extending out of pier tube.
  • Pier Cap: 5.0" wide x 9.0" long x 1" thick plate with confining ring welded to one side. Yield strength = 50 ksi (min.), tensile strength = 65 ksi (min.).
  • All-Thread Rod: 0.75" diameter x 16" long, zinc plated, Grade B7, tensile strength = 125 ksi [min.].

-- View Our Push Pier System Product Specifications document --

Foundation Supportworks™ Model 288 Capacity Summary

Soil Strength Parameters(2)

Allowable System Capacity(1,2,3,4,5) (kips)

Allowable System Capacity(1,2,3,4,5) (kips)

Soil Type

Consistency/
Relative Denisty

SPT, N-Value

Cohesion (psf)

Friction Angle (degrees)

48" Ext. Sleeve

30" Ext. Sleeve

Clay

Very Soft

< 2

< 250

-

23.5

19.2

Clay

Soft

2-3

250-500

- 27.0

21.5

Clay

Medium Stiff

4-7

501-1,000

-

32.0

23.9

Clay

Stiff

8-15

1,001-2,000

-

34.5

26.9

Clay

Very Stiff

16-31

2,001-4,000

-

34.5

30.8

Sand

Very Loose

< 3

-

26-30

33.0

24.2

Sand

Loose

4-9

-

28-34

33.0

24.2

Sand

Medium

10-29

-

30-36

34.0

26.3

Sand

Dense

30-39

-

34-40

34.5

27.2

(1) ‐ Retrofit brackets shall be used for support of structures that are considered to be fixed from translation. Structures that are not fixed from translation shall be braced in some other manner prior to installing retrofit bracket systems.

(2) ‐ Allowable capacities are based on continuous lateral soil confinement in soils with SPT blow counts as listed. Piles with exposed unbraced lengths or piles placed in fluid soils should be evaluated on a case by case basis by the project

(3) ‐ Allowable capacities consider a loss in steel thickness doe to corrosion. Scheduled thickness losses are for a period of 50 years and are in accordance with ICC‐ES AC358.

(4) ‐ Allowable capacities assume a concrete footing with a minimum compressive strength (f'c) = 2,500 psi.

(5) ‐ Allowable capacities with FS350BV retrofit bracket.

-- View Our Push Pier System Product Specifications document --

Foundation Supportworks™ Model 350 Pier System Specifications

  • Bracket: Weldment manufactured from 0.38”, 0.50”, and 0.63” thick steel plate, Yield strength = 36 ksi (min.), tensile strength = 58 ksi (min.).
  • External Sleeve: Ø4.000” x 0.226” wall x 48” long with sleeve collar welded to one end. Yield strength = 50 ksi (min.), tensile strength = 62 ksi (min.).
  • Pier Starter Tube:Ø3.500” x 0.165” wall x 50” long, triple-coated in-line galvanized. Yield strength = 50 ksi (min.), tensile strength = 55 ksi (min.). Ø4.000” x 0.226” wall x 1” long friction reducing collar welded to one end.
  • Pier Tube: Ø3.500” x 0.165” wall x 36” long, triple-coated in-line galvanized. Yield strength = 50 ksi (min.), tensile strength = 55 ksi (min.). Ø3.125” x 0.180” wall x 6” long internal coupler at one end with 3” extending out of pier tube.
  • Pier Cap: 4.00” wide x 8.50” long x 1.25” thick plate with pier locator plate welded to one side. Yield strength = 50 ksi (min.), tensile strength = 65 ksi (min.).
  • All-Thread Rod: Ø7/8” x 18” long, zinc plated. Grade B7, tensile strength = 125 ksi (min.).

-- View Our Push Pier System Product Specifications document --

Foundation Supportworks™ Model 350 Capacity Summary

Soil Strength Parameters(2)

Allowable System Capacity (1,2,3,4,5) (kips)

Soil Type

Consistency/Relative Density

SPT, N-value (blows/ft)

Cohesion (psf)

Friction Angle (degrees)

Clay

Very Soft

< 2

< 250

-

32.5

Clay

Soft

2-3

250-500

- 36.5

Clay

Medium Stiff

4-7

501-1,000

-

41.5

Clay

Stiff

8-15

1,001-2,000

-

43.5

Clay

Very Stiff

16-31

2,001-4,000

-

43.5

Sand

Very Loose

< 3

-

26-30

43.5

Sand

Loose

4-9

-

28-34

43.5

Sand

Medium

10-29

-

30-36

44.0

Sand

Dense

30-39

-

34-40

44.0

(1) ‐ Retrofit brackets shall be used for support of structures that are considered to be fixed from translation. Structures that are not fixed from translation shall be braced in some other manner prior to installing retrofit bracket systems.

(2) ‐ Allowable capacities are based on continuous lateral soil confinement in soils with SPT blow counts as listed. Piles with exposed unbraced lengths or piles placed in fluid soils should be evaluated on a case by case basis by the project

(3) ‐ Allowable capacities consider a loss in steel thickness doe to corrosion. Scheduled thickness losses are for a period of 50 years and are in accordance with ICC‐ES AC358.

(4) ‐ Allowable capacities assume a concrete footing with a minimum compressive strength (f'c) = 2,500 psi.

(5) ‐ Allowable capacities with FS350BV retrofit bracket.

-- View Our Push Pier System Product Specifications document --

Foundation Supportworks™ Model 400 Pier System Specifications

  • Bracket: Weldment manufactured from steel plates with integrated pipe sleeve. Steel plate: 0.38” and 0.50” thick steel plate, yield strength = 36 ksi (min.), tensile strength = 58 ksi (min.). Pipe sleeve: Ø4.50” x 0.237” wall x 14.50” long. ASTM A53 Grade B Type E & S, yield strength = 35 ksi (min.), tensile strength = 60 ksi (min.).
  • Pier Starter Tube:Ø4.00” x 0.226” wall x 36” long. ASTM A500 Grade B or C, yield strength = 50 ksi (min.), tensile strength = 62 ksi (min.). Ø4.50” x 0.237” wall x 1” long friction reducing collar welded to one end.
  • Pier Tube:Ø4.00” x 0.226” wall x 36” long. ASTM A500 Grade B or C, yield strength = 50 ksi (min.), tensile strength = 62 ksi (min.). Ø3.50” x 0.216” wall x 8” long internal coupler at one end with 4” extending out of pier tube.
  • Pier Cap: 4.00” wide x 8.50” long x 1.25” thick plate with pier locator plate welded to one side. ASTM A572 Grade 50, yield strength = 50 ksi (min.), tensile strength = 65 ksi (min.). All-Thread Rod: Ø0.875” x 18” long, zinc plated. ASTM A193 Grade B7, tensile strength = 125 ksi (min.).

-- View Our Push Pier System Product Specifications document --

Foundation Supportworks™ Model 400 Capacity Summary

Allowable System Capacity: 39,000 lbs. (with FS400BV Bracket)

Notes:

1.Retrofit brackets shall be used for support of structures that are considered to be fixed from translation. Structures that are not fixed from translation shall be braced in some other manner prior to installing retrofit bracket systems.

2.Concrete bearing assumes a minimum compressive strength (f’c) of 2,500 psi. Local concrete bending and other local design checks should be evaluated on a case by case basis by the project engineer.

3.Mechanical capacity is based on continuous lateral soil confinement in soils with SPT blow counts ≥ 4. Piles with exposed unbraced lengths or piles placed in weaker or fluid soils should be evaluated on a case by case basis by the project engineer.

-- View Our Push Pier System Product Specifications document --


Design Considerations

Push piers are installed directly adjacent to the existing structure utilizing side-load brackets. This introduces eccentricity into the system. The Model 288 Push Pier System incorporates an external sleeve at the top of the pier to aid in resisting the bending forces generated by this loading condition. This helps preserve the axial compressive capacity of the pier shaft. The external sleeve extends through and below the foundation bracket to essentially create a bracket that is 48 inches tall.

The moment or bending force is localized within a relatively short distance below the bracket. Although the bending force is dissipated quickly by the pier bearing against the confining soil, it is significant and cannot be ignored. The depth or length of sleeve and pier over which the bending force dissipates is a function of the soil stiffness near the surface. The depth is greater in soft clay and loose sand, and less in stiff clay and dense sand. In soft or loose soils, a small portion of the bending force may be transferred to the pier below the sleeve, thereby reducing the pier's allowable axial compressive capacity. A modified, lower capacity system is also available with a shorter, 30-inch long sleeve for low headroom applications.

Friction Reducing Collar

The first pier section advanced into the ground includes a larger-diameter "friction reducing collar" welded to the lead end. This collar, being larger in diameter than the pier tube, effectively creates annular space around the pier as it is advanced through most clayey soils. In soft clay or clean sand and gravel, an annular space may only temporarily be created. However, the larger diameter collar causes soil disturbance or remolding to occur, which also significantly reduces frictional resistance on the outside surface of the pier during driving. The result is a driven pier that generates most of its capacity in end bearing. Over time, the soils surrounding the pier relax back into the annular space and against the pier shaft. This provides an additional frictional component to the pier's capacity. Even though this frictional capacity may be significant, it is conservatively ignored in the determination of the pier's factor of safety against pier settlement.

Serving ON including the Greater Toronto area
Our Ontario Service Area
Cities in Province of Ontario
Acton
Ajax
Alberton
Algonquin Highlands
Allanburg
Allenford
Alliston
Alma
Alton
Ancaster
Angus
Annan
Ariss
Arkell
Ashburn
Aurora
Ayr
Badjeros
Bala
Baldwin
Ballinafad
Barrie
Baysville
Beamsville
Beaumaris
Beaverton
Beeton
Belfountain
Belle Ewart
Belwood
Berkeley
Bethany
Binbrook
Blackstock
Bloomingdale
Blue Mountains
Bobcaygeon
Bognor
Bolsover
Bolton
Bond Head
Borden
Bowmanville
Bracebridge
Bradford
Brampton
Branchton
Brantford
Brechin
Breslau
Brougham
Burlington
Burnt River
Caesarea
Caistor Centre
Caledon
Caledon East
Caledon Village
Caledonia
Cambray
Cambridge
Cameron
Campbellcroft
Campbellville
Campden
Canfield
Cannington
Carlisle
Cavan
Cayuga
Cedar Point
Cedar Valley
Chatsworth
Cheltenham
Christian Island
Churchill
Claremont
Clarksburg
Coboconk
Cobourg
Coldwater
Collingwood
Concord
Conestogo
Cookstown
Copetown
Courtice
Creemore
Crystal Beach
Cumberland Beach
Desboro
Dobbinton
Dundalk
Dundas
Dunnville
Dunsford
Duntroon
Eagle Lake
East Gwillimbury
East York
Eden Mills
Egbert
Elmvale
Elora
Erin
Etobicoke
Everett
Fenelon Falls
Fenwick
Feversham
Fisherville
Flesherton
Floradale
Fonthill
Fort Erie
Freelton
Georgetown
Gilford
Glen Huron
Glen Morris
Glencairn
Gooderham
Goodwood
Gormley
Grand Valley
Grassie
Gravenhurst
Greenbank
Greenwood
Grimsby
Guelph
Guelph-eramosa
Hagersville
Haliburton
Halton Hills
Hamilton
Hampton
Hannon
Hawkestone
Hawkesville
Haydon
Heathcote
Heidelberg
Hepworth
Hillsburgh
Hillsdale
Holland Centre
Holland Landing
Honey Harbour
Honeywood
Hornby
Hornings Mills
Huntsville
Inglewood
Innisfil
Irondale
Jacksons Point
Janetville
Jarvis
Jerseyville
Jordan Station
Kemble
Kendal
Keswick
Kettleby
Kilworthy
Kimberley
King City
Kinmount
Kirkfield
Kleinburg
Lake Of Bays
Laurel
Leaskdale
Lefroy
Leith
Limehouse
Lindsay
Linwood
Lions Head
Lisle
Little Britain
Locust Hill
Longford Mills
Loretto
Lowbanks
Lynden
Mactier
Manilla
Mansfield
Maple
Mar
Markdale
Markham
Maryhill
Maxwell
Midhurst
Midland
Milford Bay
Millbrook
Miller Lake
Millgrove
Milton
Minden
Minesing
Minett
Mississauga
Moffat
Moonstone
Morriston
Mount Albert
Mount Hope
Nanticoke
Nestleton Station
New Dundee
New Lowell
Newcastle
Newmarket
Newtonville
Niagara Falls
Niagara On The Lake
Nobleton
Norland
North York
Norval
Nottawa
Oakville
Oakwood
Ohsweken
Orangeville
Orillia
Oro
Oro Station
Orono
Orton
Oshawa
Palgrave
Pefferlaw
Penetanguishene
Perkinsfield
Petersburg
Phelpston
Pickering
Pontypool
Port Carling
Port Colborne
Port Dover
Port Elgin
Port Hope
Port Mcnicoll
Port Perry
Port Robinson
Port Sandfield
Port Severn
Port Sydney
Priceville
Prince Albert
Proton Station
Puslinch
Queenston
Queensville
Rama
Ravenna
Richmond Hill
Ridgeville
Ridgeway
River Drive Park
Roches Point
Rockton
Rockwood
Rosemont
Rosseau
Sandford
Sauble Beach
Scarborough
Schomberg
Seagrave
Sebright
Selkirk
Severn Bridge
Shakespeare
Shallow Lake
Shanty Bay
Sharon
Sheffield
Shelburne
Sherkston
Singhampton
Smithville
Southampton
St Agatha
St Anns
St Catharines
St Clements
St Davids
St Jacobs
Stayner
Stevensville
Stokes Bay
Stoney Creek
Stouffville
Sunderland
Sutton West
Tara
Tavistock
Terra Cotta
Thornbury
Thornhill
Thornton
Thorold
Tobermory
Toronto
Torrance
Tottenham
Townsend
Township Of Wilmot
Troy
Udora
Unionville
Utopia
Utterson
Uxbridge
Vaughan
Victoria Harbour
Vineland
Vineland Station
Virgil
Wainfleet
Wallenstein
Walters Falls
Warminster
Wasaga Beach
Washago
Waterdown
Waubaushene
Welland
Wellandport
Wellesley
West Guilford
West Montrose
Whitby
Whitevale
Wiarton
Williamsford
Willow Beach
Windermere
Woodbridge
Woodville
Wyebridge
Wyevale
York
York.
Zephyr

Cities in Whitchurch County, ON
Stouffville

Please call us at: 1-888-370-1132
bild
TCA Logo WSIB Logo